{"product_id":"airins-sniffer4d-nano-2-plus-base-unit","title":"AIRINS Sniffer4D Nano 2 Plus Base Unit","description":"\u003ch2\u003eSniffer4D Nano 2 Plus Base Unit: Standardize Fleet Wide Gas Detection Across Five Modular Slots\u003c\/h2\u003e\n\u003cp\u003eFleet operators running air quality or HAZMAT monitoring programs need a sensor platform that scales across airframes without retraining crews on new hardware every time. The Sniffer4D Nano 2 Plus Base Unit meets that requirement with five reconfigurable module slots capable of sensing six gas parameters per flight, deployed natively on the DJI Matrice 4 series through DJI Dock 3.\u003c\/p\u003e\n\u003cp\u003eEnterprise UAS programs rarely standardize on one airframe, which is why the base unit extends past its native E-Port connection through optional integration kits. The same 8.5 ounce (240 gram) unit mounts on the Matrice 400, Matrice 4E and 4T, and Matrice 350 and 300, so a single procurement decision covers an entire mixed fleet.\u003c\/p\u003e\n\u003ch3\u003eKey Features and Benefits\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eFive module slots: reconfigure detection coverage for any deployment scenario.\u003c\/li\u003e\n\u003cli\u003eIP55 protection: fleet units withstand rain across every outdoor deployment.\u003c\/li\u003e\n\u003cli\u003eNative E-Port design: deploys instantly across Matrice 4D and 4TD.\u003c\/li\u003e\n\u003cli\u003eIntegrated weather sensor: adds temperature, humidity, and pressure data automatically.\u003c\/li\u003e\n\u003cli\u003eTwelve hour data buffer: protects mission records through any signal loss.\u003c\/li\u003e\n\u003cli\u003eRemote status monitoring: six LEDs report sensor and link health.\u003c\/li\u003e\n\u003cli\u003eOnboard 32GB storage: secures every mission log in CSV format.\u003c\/li\u003e\n\u003cli\u003eSwarm architecture: coordinate multiple deployed units from a single dashboard.\u003c\/li\u003e\n\u003cli\u003ePSDK compatible payload: control operations directly from DJI Pilot 2.\u003c\/li\u003e\n\u003cli\u003eRapid air intake: accelerates gas detection across every installed module.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cdiv style=\"position: relative; width: 100%; padding-bottom: 56.25%; text-align: center;\"\u003e\n  \u003ciframe src=\"https:\/\/www.youtube.com\/embed\/BgCnozaj_LE?si=gDU6v7TYEIxGJ-dn\" title=\"YouTube video player\" style=\"position: absolute; top: 0; left: 50%; transform: translateX(-50%); width: 100%; height: 100%;\" frameborder=\"0\" allow=\"accelerometer; autoplay; clipboard-write; encrypted-media; gyroscope; picture-in-picture; web-share\" referrerpolicy=\"strict-origin-when-cross-origin\" allowfullscreen\u003e\u003c\/iframe\u003e\n\u003c\/div\u003e\n\u003ch3\u003eBuilt for Continuity at Fleet Scale\u003c\/h3\u003e\n\u003cp\u003eEnterprise deployments live or die on data continuity, and the Base Unit is built around that requirement. An IP55 rated housing and active air intake keep sensing reliable across wind, rain, and variable field conditions, while encrypted transmission and a twelve hour retrieval buffer prevent gaps in the record when connectivity drops. Swarm support extends that reliability across a fleet, letting one team monitor multiple deployed units from a single dashboard, and the onboard 32GB card gives every mission a local backup. That architecture reduces both data loss and the overhead of managing separate systems.\u003c\/p\u003e\n\u003ch3\u003eCompatibility and System Integration\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eMatrice 4D\/4TD (hardware included): connects to the aircraft's E-Port, Dock 3 ready.\u003c\/li\u003e\n\u003cli\u003eMatrice 400 Integration Kit (sold separately): integrates the unit via mounting bracket.\u003c\/li\u003e\n\u003cli\u003eMatrice 4E\/4T Integration Kit (sold separately): deploys unit with matching mounting bracket.\u003c\/li\u003e\n\u003cli\u003eMatrice 350\/300 Integration Kit (sold separately): extends fleet wide platform coverage further.\u003c\/li\u003e\n\u003cli\u003eDJI FlightHub 2 (third party software): centralizes payload control across a fleet.\u003c\/li\u003e\n\u003cli\u003eDJI Pilot 2 (included with DJI remote controller): streams live gas data.\u003c\/li\u003e\n\u003cli\u003eAIRINS.ai platform (included, perpetual license): converts fleet data into shareable structured reports.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eApplications and Use Cases\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003ePipeline and facility inspection: locate gas leaks across distributed infrastructure networks.\u003c\/li\u003e\n\u003cli\u003eLandfill program monitoring: quantify methane and odor emissions at scale.\u003c\/li\u003e\n\u003cli\u003eEmergency HAZMAT deployment: characterize hazardous concentrations before personnel are committed.\u003c\/li\u003e\n\u003cli\u003eRegional air quality programs: build pollutant and particulate maps across territories.\u003c\/li\u003e\n\u003cli\u003eIndustrial compliance surveys: document emissions across manufacturing and chemical portfolios.\u003c\/li\u003e\n\u003cli\u003eMaritime fuel compliance: verify sulfur output across vessel exhaust operations.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eMatching Sensor Modules to Your Program's Requirements\u003c\/h3\u003e\n\u003cp\u003eEvery Sniffer4D Nano 2 Plus Base Unit ships as an empty five-slot platform, which means the module selection is what turns a base unit into a program-specific detection system. Use the table below to compare detection method, range, and sensitivity across the full module lineup before standardizing a configuration across your fleet.\u003c\/p\u003e\n\u003cstyle\u003e\n  .fb-df-wrap {\n    width: 100%;\n    max-width: 1200px;\n    margin: 0 auto;\n    padding: 0 15px;\n    box-sizing: border-box;\n    color: #1f2937;\n  }\n  .fb-df-wrap *,\n  .fb-df-wrap *::before,\n  .fb-df-wrap *::after { box-sizing: border-box; }\n  .fb-df-scroll {\n    width: 100%;\n    overflow-x: auto;\n    -webkit-overflow-scrolling: touch;\n    border: 1px solid #dce3eb;\n    border-radius: 8px;\n    margin: 20px 0 0;\n  }\n  .fb-df-table {\n    width: 100%;\n    min-width: 620px;\n    table-layout: fixed;\n    border-collapse: collapse;\n    background: #ffffff;\n  }\n  .fb-df-table th,\n  .fb-df-table td {\n    padding: 13px 14px;\n    border: 1px solid #dce3eb;\n    text-align: left;\n    vertical-align: top;\n    font-size: 13px;\n    line-height: 1.5;\n    overflow-wrap: anywhere;\n  }\n  .fb-df-table thead th {\n    background: #127ABA;\n    color: #ffffff;\n    font-size: 13px;\n  }\n  .fb-df-table thead th:first-child {\n    width: 200px;\n    background: #0d5f92;\n  }\n  .fb-df-table tbody th {\n    width: 200px;\n    background: #f0f7fc;\n    color: #127ABA;\n    font-weight: 700;\n  }\n  .fb-df-table tbody tr:nth-child(even) td { background: #f8fafc; }\n  .fb-df-table.sticky-col thead th:first-child,\n  .fb-df-table.sticky-col tbody th {\n    position: sticky;\n    left: 0;\n    z-index: 2;\n    box-shadow: 2px 0 4px -1px rgba(0,0,0,0.10);\n  }\n  .fb-df-table.sticky-col thead th:first-child { z-index: 3; }\n  .fb-df-table tbody tr {\n    transition: background-color 0.15s ease, box-shadow 0.15s ease, transform 0.15s ease;\n  }\n  .fb-df-table tbody tr:hover {\n    background-color: #ffffff;\n    box-shadow: 0 4px 12px rgba(0,0,0,0.10);\n    transform: translateY(-1px);\n    position: relative;\n    z-index: 1;\n  }\n  .fb-df-table tbody tr:hover td,\n  .fb-df-table tbody tr:hover th { background-color: #ffffff; }\n  .fb-df-scroll-note {\n    margin: 10px 0 24px;\n    color: #6b7280;\n    font-size: 13px;\n    font-style: italic;\n  }\n  @media screen and (max-width: 749px) {\n    .fb-df-table { min-width: 520px; }\n    .fb-df-table thead th:first-child,\n    .fb-df-table tbody th { width: 150px; }\n    .fb-df-table th,\n    .fb-df-table td { padding: 9px 10px; font-size: 12px; }\n  }\n\u003c\/style\u003e\n\u003cdiv class=\"fb-df-wrap\"\u003e\n\u003cdiv class=\"fb-df-scroll\"\u003e\n\u003ctable class=\"fb-df-table sticky-col\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth scope=\"col\"\u003eModule\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eDetection Method\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eRange\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eLimit of Detection\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eBest For\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003ePM 1.0, 2.5, 10 (Particulate Matter)\u003c\/th\u003e\n\u003ctd\u003eLight scattering\u003c\/td\u003e\n\u003ctd\u003e5 to 1,000 μg\/m³\u003c\/td\u003e\n\u003ctd\u003e5 μg\/m³\u003c\/td\u003e\n\u003ctd\u003eGeneral environmental monitoring\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eTSP \/ PM 100 (Total Suspended Particulates)\u003c\/th\u003e\n\u003ctd\u003eLight scattering\u003c\/td\u003e\n\u003ctd\u003e30 to 3,000 μg\/m³\u003c\/td\u003e\n\u003ctd\u003e50 μg\/m³\u003c\/td\u003e\n\u003ctd\u003eGeneral environmental monitoring. Uses all 5 internal slots as a standalone build, cannot pair with other modules.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eO3+NO2 (Ozone and Nitrogen Dioxide)\u003c\/th\u003e\n\u003ctd\u003eElectrochemistry\u003c\/td\u003e\n\u003ctd\u003e0 to 11 ppm\u003c\/td\u003e\n\u003ctd\u003e10 ppb\u003c\/td\u003e\n\u003ctd\u003eGeneral environmental monitoring, photochemical oxidant tracking\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eNO2 (Nitrogen Dioxide)\u003c\/th\u003e\n\u003ctd\u003eElectrochemistry\u003c\/td\u003e\n\u003ctd\u003e0 to 11 ppm\u003c\/td\u003e\n\u003ctd\u003e10 ppb\u003c\/td\u003e\n\u003ctd\u003eGeneral environmental monitoring, HAZMAT response, ship fuel sulfur monitoring\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eCO (Carbon Monoxide)\u003c\/th\u003e\n\u003ctd\u003eElectrochemistry\u003c\/td\u003e\n\u003ctd\u003e0 to 11 ppm\u003c\/td\u003e\n\u003ctd\u003e0.05 ppm\u003c\/td\u003e\n\u003ctd\u003eGeneral environmental monitoring, HAZMAT response\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eSO2 (Sulfur Dioxide)\u003c\/th\u003e\n\u003ctd\u003eElectrochemistry\u003c\/td\u003e\n\u003ctd\u003e0 to 15 ppm\u003c\/td\u003e\n\u003ctd\u003e0.03 ppm\u003c\/td\u003e\n\u003ctd\u003eGeneral environmental monitoring, HAZMAT response, ship fuel sulfur monitoring\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eH2S (Hydrogen Sulfide)\u003c\/th\u003e\n\u003ctd\u003eElectrochemistry\u003c\/td\u003e\n\u003ctd\u003e0 to 90 ppm\u003c\/td\u003e\n\u003ctd\u003e0.03 ppm\u003c\/td\u003e\n\u003ctd\u003eGeneral environmental monitoring, oil and gas leak detection, HAZMAT response\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eNH3 (Ammonia)\u003c\/th\u003e\n\u003ctd\u003eElectrochemistry\u003c\/td\u003e\n\u003ctd\u003e0 to 100 ppm\u003c\/td\u003e\n\u003ctd\u003e1 ppm\u003c\/td\u003e\n\u003ctd\u003eOdor detection, HAZMAT response\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eOU (Odor Unit)\u003c\/th\u003e\n\u003ctd\u003eElectrochemistry\u003c\/td\u003e\n\u003ctd\u003e0 to 10 ppm\u003c\/td\u003e\n\u003ctd\u003e0.1 ppm\u003c\/td\u003e\n\u003ctd\u003eOdor detection, general environmental monitoring\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eTVOC (Total Volatile Organic Compounds)\u003c\/th\u003e\n\u003ctd\u003ePhotoionization\u003c\/td\u003e\n\u003ctd\u003e0 to 50 ppm\u003c\/td\u003e\n\u003ctd\u003e0.02 ppm\u003c\/td\u003e\n\u003ctd\u003eGeneral environmental monitoring, oil and gas leak detection, HAZMAT response\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eHCHO (Formaldehyde)\u003c\/th\u003e\n\u003ctd\u003eSolid state electrochemistry\u003c\/td\u003e\n\u003ctd\u003e0 to 100 ppm\u003c\/td\u003e\n\u003ctd\u003e1 ppm\u003c\/td\u003e\n\u003ctd\u003eContact Dronefly support for more information\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003cp class=\"fb-df-scroll-note\"\u003eScroll horizontally to view all columns on smaller screens.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cp\u003eTwo configurations replace the entire five-slot array rather than occupying one slot: the standalone TSP\/PM 100 module and the separate Sniffer4D Nano 2 Plus Methane unit, built around dedicated multi-pass TDLAS technology. The optional External Measurement Module for wind, temperature, and humidity mounts independently and sits outside the five-slot module family. Work with your Dronefly specialist to lock in a module standard before scaling the configuration across your fleet.\u003c\/p\u003e\n\u003cp\u003eThe Sniffer4D Nano 2 Plus Base Unit gives enterprise UAS programs a single sensor platform that scales across gas hazards instead of a fleet of single purpose devices. Modular detection, encrypted data continuity, and cross platform integration let one architecture support pipeline, landfill, HAZMAT, and air quality programs alike.\u003c\/p\u003e\n\u003cp\u003eDronefly helps you configure the Sniffer4D Nano 2 Plus Base Unit as part of a fully integrated UAV solution, matching module selection and integration kits to your fleet's specific Matrice platforms. As your dedicated drone partner, our specialists design the configuration around your program's mission profile, not just a single order.\u003c\/p\u003e\n\u003cp\u003eBuy the Sniffer4D Nano 2 Plus Base Unit through Dronefly and equip your fleet with gas detection built to scale.\u003c\/p\u003e","brand":"AIRINS","offers":[{"title":"Default Title","offer_id":52753917247781,"sku":"S-AIN-S4D-N2P-BASE","price":2744.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0884\/4908\/9829\/files\/AIRINSSniffer4DNano2PlusBaseUnit.webp?v=1783653837","url":"https:\/\/www.dronefly.com\/products\/airins-sniffer4d-nano-2-plus-base-unit","provider":"DroneFly","version":"1.0","type":"link"}