Skip to product information
1 of 2

MicaSense RedEdge-P Blue Multispectral kit

MicaSense RedEdge-P Blue Multispectral kit

Regular price $8,495.00
Regular price Sale price $8,495.00
Sale Sold out
SKU S-MICA-REP-BLUE MPN 805-00108
  • Coastal blue multispectral sensor for water-focused analysis
  • Expandable into dual or triple RedEdge-P configurations
  • Supports synchronized capture of up to fifteen bands
  • Global shutter sensors ensure distortion-free imaging
  • Radiometrically calibrated for repeatable quantitative results
  • Pan-sharpened output supports fine spatial resolution
  • DJI SkyPort compatible enterprise payload integration
  • Includes DLS 2 and calibration reflectance panel
View full details
  • Description
  • Specifications
  • In the Box
  • FAQ

MicaSense RedEdge-P Blue Multispectral Kit: coastal multispectral intelligence with expandable band architecture

The MicaSense RedEdge-P Blue Multispectral Kit is purpose-built for enterprise users performing precision agriculture, environmental monitoring, and water-focused aerial surveys. As a standalone system, it captures five multispectral bands optimized for coastal and aquatic analysis using synchronized global-shutter sensors and radiometric calibration. Its ocean blue wavelength enables enhanced visibility in shallow water environments and improved vegetation stress detection.

Built on the modular RedEdge-P platform, the RedEdge-P Blue also supports expansion into dual and triple sensor configurations, allowing teams to increase spectral coverage while maintaining consistent data quality and operational workflows.

Coastal-optimized multispectral system and expansion features

  • Standalone coastal blue multispectral sensor for water and vegetation analysis
  • Ocean blue band enhances shallow water and aquatic environment monitoring
  • Global shutter sensors eliminate motion distortion during survey flights
  • Radiometric calibration supports repeatable quantitative data collection
  • Modular architecture supports expansion into dual sensor configurations
  • Dual systems allow selection of up to ten multispectral bands
  • Expandable into RedEdge-P Triple configuration with fifteen bands
  • Synchronized multi-sensor capture preserves temporal and spatial alignment

Reliable spatial resolution for analytical workflows

The RedEdge-P Blue captures multispectral imagery at 1456 × 1088 pixels per band, paired with a 2464 × 2056 pixel panchromatic sensor and a 5.1 MP RGB output aligned across all bands. At 120 m (≈400 ft) AGL, the system delivers a ground sample distance of 7.7 cm (3 in) per multispectral band and 3.98 cm (1.5 in) for the panchromatic band. With pan-sharpening applied during post-processing, spatial resolution can reach 2 cm (0.8 in) per pixel. Global shutter architecture ensures distortion-free imagery during motion-intensive missions.

Scalable spectral coverage from single to triple configurations

The RedEdge-P Blue Multispectral Kit is designed to scale with operational requirements. Used independently, it provides coastal-optimized multispectral data for water and vegetation analysis. When paired with a RedEdge-P or RedEdge-P Green sensor, the system forms a dual configuration supporting up to ten selectable bands from a fifteen-band ecosystem.

When combined with both RedEdge-P and RedEdge-P Green sensors, it becomes part of the RedEdge-P Triple configuration, enabling synchronized capture of all fifteen multispectral bands for advanced pigment analysis, stress detection, and research-grade spectral differentiation.

Platform compatibility and workflow integration

  • Compatible with DJI SkyPort-equipped enterprise aircraft (Matrice 300/350)
  • Supports single, dual, and triple sensor mounting configurations
  • Includes DLS 2 downwelling light sensor with integrated GPS
  • Calibrated reflectance panel supports radiometric correction
  • Interfaces include Ethernet, serial, USB, and configurable GPIO
  • CFexpress storage supports high-speed raw DNG capture
  • Protective hard carrying case included for field deployment

Enterprise use cases and operational scenarios

  • Precision agriculture analysis: crop vigor, chlorophyll efficiency, stress detection
  • Water quality monitoring: algae blooms, sediment suspension, aquatic vegetation
  • Coastal and near-shore mapping: tidal zones, wetlands, shoreline environments
  • Environmental monitoring: ecosystem health and long-term change tracking
  • Vegetation research: species differentiation and invasive plant identification
  • Forestry assessment: canopy condition and vegetation classification
  • Conservation programs: biodiversity monitoring and habitat restoration
  • Academic research: high-band-count multispectral data acquisition

Engineered for mission reliability and system scalability

The RedEdge-P Blue Multispectral Kit is engineered for professional operations requiring dependable data, scalable architecture, and long-term consistency. Double radiometric calibration using a downwelling light sensor and reflectance panel supports reliable datasets across changing light conditions. Its modular design enables organizations to deploy a single coastal-focused sensor today and expand into dual or triple configurations as analytical demands grow, without altering established workflows or processing pipelines.

The MicaSense RedEdge-P Blue Multispectral Kit delivers coastal-optimized spectral intelligence with a clear path to higher band counts. From standalone surveys to fully synchronized fifteen-band systems, it supports confident, data-driven decision-making across land and water environments.

Order from Dronefly today — the West Coast’s trusted enterprise UAV source.

Spectral Bands

  • Multispectral bands: 5 total (ocean/coastal blue, green, red, red edge 705, red edge 740)
  • Ocean blue band wavelength: 444 nm center, 28 nm bandwidth

Sensor Resolution and Output

  • Multispectral sensor resolution: 1456 × 1088 pixels (1.6 MP per band)
  • Panchromatic sensor resolution: 2464 × 2056 pixels (5.1 MP)
  • RGB output: 5.1 MP, global shutter, aligned with all spectral bands
  • Shutter type: Global shutter across all sensors

Ground Sample Distance and Pansharpening

  • Ground sample distance (multispectral): 7.7 cm / 3 in per pixel at 120 m (~400 ft) AGL
  • Ground sample distance (panchromatic): 3.98 cm / 1.5 in per pixel at 120 m (~400 ft) AGL
  • Pan-sharpened output resolution: 2 cm / 0.8 in per pixel with post-processing

Capture and Storage

  • Capture rate: Up to 3 raw DNG images per second
  • Storage media: CFexpress card

Power

  • External power input: 7.0–25.2 V
  • Power consumption: 11 W standby, 14 W average, 20 W peak

Optics and Field of View

  • Field of view (multispectral): 50° HFOV × 38° VFOV
  • Field of view (panchromatic): 44° HFOV × 38° VFOV

Calibration

  • Radiometric calibration: Double calibration using DLS 2 light sensor and reflectance panel

Interfaces

  • Interfaces: Ethernet, serial, USB 2.0 (WiFi), configurable GPIO, PPS input/output

Environmental and Protection

  • Operating temperature (no airflow): 0–40 °C (32–104 °F)
  • Operating temperature (with airflow >0.5 m/s / 1.1 mph): 0–50 °C (32–122 °F)
  • Ingress protection rating: IP4X

Expansion and Synchronization

  • Modular expansion: Compatible with RedEdge-P and RedEdge-P Green for dual or triple configurations
  • Multi-sensor synchronization: Supported when used in dual or triple systems
  • 1x RedEdge-P Sensor (Blue)
  • 1x USB Wi-Fi dongle
  • 1x Lens cover
  • 1x Integration cables
  • 1x Assorted mounting hardware
  • 1x CFexpress card
  • 1x Hard carrying case
  • 1x Start guide
What is the MicaSense RedEdge-P Blue Multispectral Kit designed for?

The MicaSense RedEdge-P Blue Multispectral Kit is designed for coastal, agricultural, and environmental multispectral analysis. It supports vegetation monitoring, water quality assessment, and habitat mapping.

Can the MicaSense RedEdge-P Blue Multispectral Kit operate as a standalone sensor?

Yes, the RedEdge-P Blue can be used independently as a coastal-optimized multispectral sensor without additional cameras.

Is the RedEdge-P Blue expandable into multi-sensor configurations?

Yes, it can be combined with RedEdge-P and RedEdge-P Green sensors to form dual or triple configurations with higher band counts.

How many bands are supported in a RedEdge-P Triple configuration?

When used as part of a RedEdge-P Triple system, the configuration supports synchronized capture of up to fifteen multispectral bands.

Does the MicaSense RedEdge-P Blue Multispectral Kit include radiometric calibration components?

Yes, the kit includes a downwelling light sensor and calibrated reflectance panel to support consistent data collection.